Standard Calibration (continued)

Step

Action

Displayed Message

Comment

G

Observe the calibration

result.

CALIBRATION COMPLETE

Calibration was

successful.

If WARNING LOW

BACKING is displayed,

calibration was successful
(for possible messages
see Section 5.1).

H

Press ESC then EXIT to
return to READY.


When calibrating gap or
reflective media, press and

hold the FEED Key until at
least one label is output.

CALIBRATION COMPLETE

Followed by...

READY

The printer is now ready
for use.








5.2.2

Advanced Entry Calibration

Advanced Entry is an alternate calibration method for special-case media types, where

sensor readings are taken using different sampling algorithms and from a list of these
readings the best algorithm is selected for manual entry into the database.

Advanced Entry Calibration should be used only when Standard Calibration proves
unsuccessful. Also, before proceeding, ensure that the ADVANCED MENU is enabled

(see Section 4.2.4) and that the SENSOR TYPE is selected (see Section 4.2.1).


Calibrate the Media Sensor using the steps below: