beautypg.com

Datamax-O'Neil H-Class Operator’s Manual User Manual

Page 155

background image

H-Class

145

F. Download the generated files to the printer – one method is the DOS copy

command:

copy small.ls lpt1: /b

G. Reset the printer by pressing and holding the CANCEL Key for approximately four

seconds.

H. After resetting, verify operation by printing a Configuration Label (see Section 4.3.5).

New language information will be printed under SYSTEM INFORMATION / OPTIONAL
LANGUAGES. (Also, the new language will appear on the display as a menu item in
SYSTEM SETTINGS / MENU LANGUAGE. These are the only methods to determine a

successful download.)

Enable the new language. Enter the menu system and go to SYSTEM SETTINGS /
MENU LANGUAGE and select the new language (A reset will occur as font validation

is performed.)

Afterward, reenter the menu system and go to SYSTEM SETTINGS / MENU
LANGUAGE and select the desired font for the language. Save the changes when
prompted.

An error has occurred if the printer displays the new language selection, but all

messages remain in English. In this case, re-check your process or contact Datamax-
O’Neil Technical Support (be ready to provide the Common.xls and DPL download

files created). Other error messages are also possible:

Menu Language Error Message

Description

Please select the entire column(s) or
the desired language(s), by clicking on

the column letter(s)

After pressing the Generate DPL File(s)
radio button, the languages to convert

were not correctly selected.

Message text may not exceed MAX =
xx designated characters for this MID

The entered message exceeds the
number of characters specified in column
C. You may not modify this number.


I. Repeat Steps A – H using the filename misc.xls to translate printer option items. This

will output small20.ls.

Advanced File Handling Information

The standard printer leaves the factory with EFIGS loaded into Module Y. At this
point, Module Y is LOCKED and will only accept additional language downloads.