Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

L

Use the buttons to set the

Gain Number determined
in the previous step. Press

ENTER to enable the
setting.

TRAN SENSOR GAIN


yyy (0 - 31)

18

This example uses Gain

Number 18.

M

Complete a table (see
example below) using new

measurements, as
follows:


(A) Raise the Printhead

Assembly. Place the
label over the Media
Sensor then lower and

latch the Printhead
Assembly. Record the

sensor reading as P.

(B) Raise the Printhead

Assembly. Place the

liner, notch, or mark
over the Media Sensor
then lower and latch

the Printhead
Assembly. Record the

sensor reading as G
(or M).


(C) Raise the Printhead

Assembly. Remove all
media from the Media
Sensor then lower and

latch the Printhead
Assembly. Record the

sensor reading as E.

TRAN SENSOR GAIN

yyy (0 - 31)
18

Where “yyy” is a
numerical value

representing the current
sensor reading.


The re-sampled
values may differ

from those
previously noted.

This is normal; do
not readjust the
Media Sensor.


Selected Gain Table

Gain Number

Paper

Gap (or Mark)

Empty

18 173 42 9