beautypg.com

Datamax-O'Neil H-Class Operator’s Manual User Manual

Page 66

background image

56

H-Class

System Settings (continued)

Menu Item

Details

INPUT MODE

Defines the type of processing that occurs when data
is received, where:

See the Class Series 2 Programmer’s Manual for

detailed information.

DPL

Processes data for standard DPL printing.

LINE

Processes data for Line Mode (template) printing.

PL-Z

Processes data for PL-Z printing.

AUTO

Identifies then activates the appropriate emulation
parser for the data.

Correct identification can be dependent upon the

HOST SETTINGS / HOST TIMEOUT (see Section

4.2.5). Also, extraneous characters may, in some
cases, render the data unrecognizable, thus
requiring manual selection of the mode.

USER LABEL MODE

Sets the printer to power-up as default, where:

ENABLED

Functions in standalone mode for quick access to user

defined formats; see Section 4.3.7.

This mode will remain active until disabled.

DISABLED

Functions in normal mode, awaiting commands from a

host.

DPL EMULATION

Allows legacy printer emulation, where:

Ignores label commands A, M, n & T; see the Class

Series 2 Programmer’s Manual for information.

STANDARD

Uses no legacy emulation, all commands recognized.

ALLEGRO

Emulates the Allegro

®

.

PRODIGY PLUS

Emulates the Prodigy Plus

®

.

PRODIGY

Emulates the Prodigy

.