beautypg.com

Datamax-O'Neil H-Class Operator’s Manual User Manual

Page 57

background image

H-Class

47

Printer Options (continued)

Menu Item

Details

LOCK AFTER WRITE

Allows the tag to be locked after programming, where:

ENABLED

Locks the tag.

DISABLED

Does not lock the tag.

RETRY ATTEMPTS

Sets the number of retry attempts, where:

(0 - 9)
3

Is the retry count before a fault is declared.

PERFORM CALIBRATION

Allows the printer to establish the tag to transducer

distance and nominal power setting, where:

YES

Initiates the process; CALIBRATING RFID will be

displayed as media is scanned for the tag location and

power, followed by TOF positioning and the
operational results where, if successful, the database

parameters will be updated.

NO

Exits the menu item without calibration.

SET DEFAULTS

Allows the RFID default values to be restored, where:

YES

Restores the default settings.

NO

Exits the menu item without changing the current

settings.