43

Printer Options (continued)

Menu Item

Details

MIN READABLE HEIGHT

Ensures bar code integrity by setting a minimum
distance for identical decodes, where:

DISABLED

Uses REDUNDANCY LEVEL to ensure bar code

integrity.

1/16 – ½ in.
(1.5 – 12.5 mm)

Sets the read height (e.g., a setting of ¼ requires .25

inches of the bar code height be 100% readable).

This distance should not exceed 50% of the
measured bar code height.

REDUNDANCY LEVEL

Ensures bar code integrity by specifying a consecutive

number of identical decodes, where:

(1X – 6X)
3X

Sets the read count (e.g., a 3X setting requires three
identical decodes to pass).

High redundancy rates and fast print speeds can

cause erroneous failures when scanning small or
multiple bar codes.

AUTO

Uses MIN READABLE HEIGHT to ensure bar code

integrity.

IGNORE NO DATA

Allows an override of the verification function, where:

DISABLED

Checks for correct bar code data in the bar code(s).

ENABLED

Ignores the data present in the bar code(s).

SET DEFAULTS

Allows the scanner default values to be restored,
where:

YES

Restores the default settings.

NO

Exits the menu item without changing the current

settings.