Media Settings


The Media Settings menu contains label and ribbon settings, and printhead maintenance
selections.

Menu Item

Details

MEDIA TYPE

Selects the printing method, where:

DIRECT THERMAL

Sets printing for heat reactive media.

THERMAL TRANSFER

Sets printing for media that requires ribbon to produce

an image.

SENSOR TYPE

Selects the Top Of Form (TOF) sensing method used
to determine the leading edge of the label, where:

GAP

Senses the gaps or notches in the media.

CONTINUOUS

Uses the LABEL LENGTH (see below) to determine the

TOF.

REFLECTIVE

Senses the reflective (black) marks on the underside

of the media.

LABEL LENGTH

Determines the length of the label when the SENSOR

TYPE is set to CONTINUOUS, where:

(0 – 99.99 in.)
04.00

Is the desired length of the format.

MAXIMUM LABEL LENGTH

Sets the distance that the printer will feed GAP or
REFLECTIVE media before declaring a TOF fault,

where:

(0 – 99.99 in.)
16.00

Is the length of travel to detect a TOF gap or mark.

This distance should be 2.5 to 3 times the label
length.

PAPER EMPTY DISTANCE

Sets the distance the printer will attempt to feed
media before declaring an Out Of Stock fault, where:

(0 – 99.99 in.)
00.25

Is the length of travel to detect the presence of media.

If using transparent or translucent media, this
setting should be longer than the label length.

LABEL WIDTH

Sets the maximum printable width. Objects extending

beyond this limit will NOT print, where:

(X.XX – X.XX in.)
X.XX

Is the maximum width; see Appendix B for the model