beautypg.com

Datamax-O'Neil H-Class Operator’s Manual User Manual

Page 80

background image

70

H-Class

Diagnostics (continued)

Menu Item

Details

TEST REWINDER

Tests the Powered Internal Rewinder, where:

PERFORM TEST
001 TIMES

Selects the number of rotations (0 - 999) to perform

and then displays the PASS / FAIL results for each
attempt.

Remove media from the rewinder before testing.

TEST GPIO

Tests the Applicator Interface Card’s GPIO function,

where:

MONITOR GPIO INPUT

SOP FEED PAUSE REPRT

1 1 1 1

i1 i2 i3 i4 i5 i6

1 1 1 1 1 1

Displays input signal logic values for Start of Print

(SOP), Feed, Pause, Reprint, and six unassigned input
lines. (The values given here are examples only.)

Unconnected lines may display a zero or one.

TEST GPIO OUTPUT

EP RL SR MO RO DR OF

1 1 1 1 1 1 1

o1 o2 o3 o4 o5 o6

1 1 1 1 1 1

Displays output signal logic values for End of Print

(EP), Ribbon Low (RL), Service Required (SR), Media
Out (MO), Ribbon Out (RO), Data Ready (DR), Option

Fault (OF), and six unassigned output lines. (The
values given here are examples only.)

To change an output signal, cursor over the
displayed state to select and then toggle it using

the UP or Down Arrow Buttons, except Data Ready
which cannot be toggled.

PRINT SIGNAL INFO

Prints a reference label (see sample below) containing

GPIO signal names, pin and port assignments,

programmed settings, and current signal states.