background image

24

H-Class

Unloading the Internal Rewinder

To unload the Internal Rewinder, open the Locking Lever, remove the Rewind Retainer, and
slip the roll of labels (and core) off the Rewind Core Adapter.



Removing the Adapter Core

To switch from label rewinding to label peeling, remove the Rewind Core Adapter as follows:


A. Remove labels from the Internal Rewinder. Open the Rewind Support (8" wide

models only).

B. Rotate the Rewind Hub so that the Tabs are in a horizontal position, as shown.

C. Using both hands, grasp the Rewind Core Adapter and, with a gentle back-and-forth

rocking motion, pull the Rewind Core Adapter off the Rewind Hub.