beautypg.com

Datamax-O'Neil H-Class Operator’s Manual User Manual

Page 60

background image

50

H-Class

Printer Options (continued)

Menu Item

Details

ERR ON PAUSE (APP2)

Sets the output when a service required fault occurs
(Applicator Interface Card Type 2 equipped only),

where:

ENABLED

Enables the output signal.

DISABLED

Disables the output signal.

REWINDER

Controls the Powered Internal Rewinder option, where:

MODE

Sets the detection method and response of the printer,
where:

DISABLED

Disables the option.

AUTO

Enables the rewinder only when a Peel and Present

option is installed; however, no error will be generated
when the Peel and Present option is not attached.

(Upon power-up, the rewinder will turn slowly to
tension the material.)

ENABLED

Enables the rewinder and generates an error if it

cannot be detected. Upon power-up, the rewinder will
turn slowly (for about 30 seconds) to tension the

material and then whenever labels move.

REWINDER ADJUSTMENT

Adjusts the amount of rewinding tension to minimize

TOF registration drift (sometimes evident when using
narrow media), where:

(-30 – 15 %)
00

Decreases or increases the nominal torque by the

percentage selected.