Performing soft system resets

The switchers have three soft resets available that restore various tiers of switcher

settings to their default settings.

Events (mode 3) reset — This function toggles the monitoring of events on

or off (if events monitoring was on, this function turns it off; if it was off, it is

turned on).

IP settings (mode 4) reset — The IP settings reset performs the following

functions:

Enables ARP program capability.

Resets the IP address to the factory default (192.168.254.254).

Resets the subnet mask to the factory default (255.255.0.0).

Resets the gateway address to its factory default (0.0.0.0).

Turns DHCP off.

Turns events off.

N

IP settings reset does not replace any user-installed firmware.

Absolute (mode 5) reset — Absolute reset restores the switcher to the default

factory conditions. This function is identical to the

Esc

ZQQQ SIS command

(see chapter 4, “Programmer’s Guide”).

Perform a soft reset of the switcher as follows:

1

.

Use an Extron Tweeker or other small screwdriver to press and hold the rear

panel Reset button until the front panel RGBHV and Audio buttons blink once

(events reset), twice (system reset), or three times (absolute reset) (figure 3-71).

I / O

RGBHV AUDIO

I / O

VIDEO AUDIO

I / O

RGBHV AUDIO

RESET

LAN

RESET

RESET

RESET

RESET

RESET

Press and

hold

the Reset button.

Press and

hold

the Reset button.

Release, then

immediately

press and release again.

Release, then

immediately

press and release again.

3 seconds

Events Reset

IP Settings

Reset

Buttons and Reset LED flash

once.

Buttons and Reset LED flash

twice.

Buttons and Reset LED flash

three times.

6 seconds

Press and

hold

the Reset button.

Release, then

immediately

press and release again.

Absolute Reset

9 seconds

1

2

3

Figure 3-71 — Whole switcher and absolute resets