Page 101: Ethernet.protocol.settings, Preliminar y

background image

5-3

MVX Plus 128 VGA A Matrix Switcher • Matrix Software

PRELIMINAR

Y

4

.

Follow the on-screen instructions. By default, the Windows installation of

the Matrix Switchers Control Program creates a C:\Program Files\Extron\

Matrix_Switcher directory, and it places three icons into a group folder named

“Extron Electronics\Matrix Switchers”. The three installed icons are:

MATRIX Switcher+ Control Program

MATRIX Switcher+ Help

Uninstall MATRIX Switcher

N

The MVX switcher can support remote control via either the rear panel Remote

RS-232/RS-422 Remote port or the front panel Configuration port.

Remote RS-232/RS-422 port — The port can be configured for either the
RS-232 or RS-422 serial communication protocol and operate at the 9600,
19200, 38400, or 115200 baud rate. See “Selecting the rear panel Remote port
protocol and baud rate” in chapter 3, “Operation”, to configure the rear panel
port from the front panel.

Configuration port — The port supports RS-232 serial communication
protocol only. The port can operate at the 9600, 19200, 38400, or 115200 baud
rate, but Extron recommends leaving this port at the 9600 baud rate. See the
Set serial port parameters command on page 4-19 to configure either port using
an SIS command.

Software operation via Ethernet

When an MVX Plus VGA A switcher is connected to an Ethernet WAN or LAN,

any number of users can operate it, locally or remotely, using the Matrix Switchers

Control Program. See “Ethernet connection” in chapter 2, “Installation”, for

installation details.
Connection to the switcher via the Ethernet is password protected. There are two

levels of password protection: administrator and user. Administrators have full

access to all MVX Plus VGA A switching capabilities and editing functions. Users

can select inputs and outputs, set and recall presets, and view all settings with

the exception of passwords. If the same password or no password is required for

logging on, all personnel log on with administrator privileges. Fields and functions

that exceed user privileges are grayed out in the Matrix Switchers Control Program

when the operator is logged on as a user.

Ethernet protocol settings

The IP Settings/Options screen (figure 5-7 on page 5-7) provides a location for

viewing and, if connected via the RS-232 link or if logged on via the LAN port as an

administrator, editing settings unique to the Ethernet interface. See “IP Settings/

Options window”, later in this chapter, for more details.