Chapter 4 Parameter Settings|DD Series


4-51

05 Door Close Parameters

This parameter can be set during operation.

Door Close initial Speed

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 2.00

Settings 0.00~120.0Hz

Door Close Distance by Initial Speed

Control mode VF

VFPG

SVC

FOCPG FOCPM

Factory setting: 0

Settings 0~65535 (Unit: pulses number)

Door Close Time by Initial Speed

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 0

Settings 0.0~20.0s

Door Close High Speed 1

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 15.00

Settings 0.00~120.0Hz

Door Close by Final Speed Begins

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 10.0

Settings 0.0~100.0% (0.0%=door completely close, 100.0%= door completely open)

Door Close Final Speed

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 5.00

Settings 0.00~120.0Hz

Door Close by Holding Speed begins

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 5.0

Settings 0.0~100.0% (0.0%=door completely close, 100.0%= door completely open)

Door Close Holding Speed

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 2.00

Settings 0.00~120.0Hz

Door Close Acceleration Time 1

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 1.0

Settings 0.1~3600sec

Door Close Deceleration Time 1

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 1.0

Settings 0.1~3600sec

Door Close Holding Torque Level

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 50.0

Settings 0.0~150.0% (Drive’s rated current)

Please refer to the diagram below and adjust door open/close curve to your requirement.