Delta 1.07 VFD-D D User Manual
Page 27
Chapter 4 Parameter Settings|DD Series
4-3
Parameter
Explanation
Settings
Factory
Setting VF VFP SVC FO
C
FO
C
00.05 Software version
Read only(Different versions will display
differently)
#.## ○ ○ ○ ○ ○
00.06 Password Input
0~9999
0~2:times of wrong password
0
○ ○ ○ ○ ○
00.07 Password Set
0~9999
0: No password set or successful input in
Pr.00-06
1: Password has been set
0
○ ○ ○ ○ ○
00.08 Control Method
0: V/f control
1: V/f Control + Encoder (VFPG)
2: Sensorless vector control (SVC)
3: FOC vector control + Encoder
(FOCPG)
8: FOC PM control (FOCPM)
0
○ ○ ○ ○ ○
00.09 Door Control Mode
0: Distance control mode
1: Reserved
2: Multi-step speed control mode
3: Speed control mode
3
○ ○ ○ ○ ○
00.10 Output Direction
0: Runs in same direction as setting
1: Runs in different direction than setting
0
○ ○ ○ ○ ○
00.11 Carrier Frequency
Selection
02~15 kHz
02~10kHz (for VFDXXXDDXXE model
only)
10
○ ○ ○ ○ ○
00.12 Auto Voltage Regulation
(AVR) Function
0: Enable AVR
1: Disable AVR
2: Disable AVR when deceleration stop
0
○ ○ ○ ○ ○
00.13 Source of the Master
Frequency Command
0: by digital keypad input
1: by external terminal
2: by RS-485 serial communication
1
○ ○ ○ ○ ○
00.14 Demo Mode
0: Disable
1: Display demo action
0
○ ○ ○ ○ ○
00.15 Frequency Testing
Command
0~120.00 Hz
0
○ ○ ○ ○ ○