Delta 1.07 VFD-D D User Manual
Page 37
Chapter 4 Parameter Settings|DD Series
4-13
Parameter
Explanation
Settings
Factory
Setting VF VFP SVC FO
C
FO
C
05.24 Door Close DC Brake
Starting Frequency
0.00~120.00Hz 0.00
○ ○ ○ ○
05.25 Door Re-open Current
Level 1
0.0~150.0% (AC drive’s rated current)
100.0 ○ ○ ○ ○ ○
05.26 Door Re-open Current
Level 1 for Acceleration
Area
100~200% (100% is Pr.05.25 setting)
150 ○ ○ ○ ○ ○
05.27 Door Re-open Current
Level 1 for Low Speed Area
0.0~150.0%(Drive’s rated current)
100.0 ○ ○ ○ ○ ○
05.28 Door Re-open Current
Level 2
0.0~150.0%(Drive’s rated current)
100.0 ○ ○ ○ ○ ○
05.29 Door Re-open Current
Level 2 for Acceleration
Area
0.0~150.0% (Drive’s rated current)
150 ○ ○ ○ ○ ○
05.30 Door Re-open Current
Level 2 for Low Speed Area
100~200%(100% is Pr.05.29 setting)
100.0 ○ ○ ○ ○ ○
05.31 Door Re-open Low Speed
Boundary
1.0~99.0%(Total door width=100%;
range between 0%~Pr.05.31 is excluded
from low speed detection area)
2.0 ○ ○ ○ ○ ○
05.32 Door Re-open Acceleration
Boundary
8.0~97.0%(Total door width =100%;
range between Pr.05.32~100% is the
acceleration area)
70.0 ○ ○ ○ ○ ○
05.33 Door Close Error
Deceleration Time
0.1~3600sec 0.4 ○ ○ ○ ○ ○
05.34 Door Re-open Detection
Time
0~10.0sec 0.2
○ ○ ○ ○ ○