Chapter 4 Parameter Settings|DD Series


4-2

4-1 Summary of Parameter Settings

00 System Parameters

: This parameter can be set during operation.

Parameter

Explanation

Settings

Factory

Setting VF VFP SVC FO

C

FO

C

00.00 Identity Code of AC motor

drive

0: 200w
2: 400w

Read

only

○ ○ ○ ○ ○

00.01 Rated Current Display of

AC motor drive

0: 1.50A
2: 2.50A

Read

only

○ ○ ○ ○ ○

00.02 Parameter Reset

0: No function
1: Parameters locked
8: Keypad locked
10: All parameters are reset to factory

setting (33.3Hz, 230V)

0

○ ○ ○ ○ ○

00.03 Start-up Display Selection 0: Display the frequency command value

(F)

1: Display the actual output frequency

(H)

2: Display the content of user-defined

unit (U)

3: Display the output current (A)

0

○ ○ ○ ○ ○

00.04 Content of Multi Function

Display

0: Display output current (A )
1: Display actual frequency (Hz)
2: Display DC-BUS voltage ( U)
3: Display output voltage( E )
4: Display power factor angle (n.)
5: Display output power (kW)
6: Display motor angle speed (HU)
7: Display the drive’s estimated output

torque (kg-m)

8: Display PG pulse input position
9: Display the electrical angle
10: Display IGBT temperature(oC)
11: Display digital input ON/OFF status
12: Display digital output ON/OFF status
13: Display current multi-step speed
14: Display the corresponding CPU pin

status of digital input

15: Display the corresponding CPU pin

status of digital input 16:Actual
output voltage when malfunction

17: Actual DC-BUS voltage when

malfunction

18: Actual output frequency when

malfunction

19: Actual output current when

malfunction

20: Actual frequency command when

malfunction

21: Door width in % or step speed
22: Door width(pulse)
23: Over modulation indication

2

○ ○ ○ ○ ○