03 feedback parameters – Delta 1.07 VFD-D D User Manual
Page 33
Chapter 4 Parameter Settings|DD Series
4-9
03 Feedback Parameters
This parameter can be set during
operation.
Parameter
Explanation
Settings
Factory
Setting VF VFP SVC FO
C
FO
C
03.00 Encoder (PG) Signal Type 0: No function
1: ABZ
7: PWM pulse
7
○
○ ○
03.01 Encoder pulse
1~25000 256
○
○ ○
03.02 Encoder Input Type Setting 0: Disable
1: Phase A leads in a forward run
command and phase B leads in a
reverse run command
2: Phase B leads in a forward run
command and phase A leads in a
reverse run command
3: Phase A is a pulse input and phase B
is a direction input. (low input=reverse
direction, high input=forward direction)
4: Phase A is a pulse input and phase B
is a direction input. (low input=forward
direction, high input=reverse direction)
5: Single-phase input
1
○
○ ○
03.03 Encoder Feedback Fault
Treatment (PGF1, PGF2)
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and stop operation
2
○
○ ○
03.04 Detection Time for Encoder
Feedback Fault
0.0~10.0sec 1.0
○
○ ○
03.05 Encoder Stall Level (PGF3) 0~120% (0:Disable)
115
○ ○ ○ ○
03-06 Encoder Stall Detection
Time
0.0~2.0sec
0.1 ○ ○ ○ ○
03.07 Encoder Slip Range
(PGF4)
0~50% (0:Disable)
50
○ ○ ○ ○
03.08 Encoder Slip Detection
Time
0.0~10.0sec
0.5 ○ ○ ○ ○
03.09 Encoder Stall and Slip Error
Treatment
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
2
○ ○ ○
03.10 Door Width Auto-tuning
Frequency
0.10~120.00Hz 5.0
○ ○ ○ ○ ○
03.11 Door Width Auto-tuning
0: Disable
1: Enable
0
○ ○ ○ ○ ○
03.12 Door Width Pulse (Unit:1) 1~9999 8800 ○ ○ ○ ○ ○
03.13 Door Width Pulse
(Unit:10000)
0~9999 (Unit:10000)
0
○ ○ ○ ○ ○