beautypg.com

03 feedback parameters – Delta 1.07 VFD-D D User Manual

Page 33

background image

Chapter 4 Parameter Settings|DD Series


4-9

03 Feedback Parameters

This parameter can be set during

operation.

Parameter

Explanation

Settings

Factory

Setting VF VFP SVC FO

C

FO

C

03.00 Encoder (PG) Signal Type 0: No function

1: ABZ
7: PWM pulse

7

○ ○

03.01 Encoder pulse

1~25000 256

○ ○

03.02 Encoder Input Type Setting 0: Disable

1: Phase A leads in a forward run

command and phase B leads in a
reverse run command

2: Phase B leads in a forward run

command and phase A leads in a
reverse run command

3: Phase A is a pulse input and phase B

is a direction input. (low input=reverse
direction, high input=forward direction)

4: Phase A is a pulse input and phase B

is a direction input. (low input=forward
direction, high input=reverse direction)

5: Single-phase input

1

○ ○

03.03 Encoder Feedback Fault

Treatment (PGF1, PGF2)

0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and stop operation

2

○ ○

03.04 Detection Time for Encoder

Feedback Fault

0.0~10.0sec 1.0

○ ○

03.05 Encoder Stall Level (PGF3) 0~120% (0:Disable)

115

○ ○ ○ ○

03-06 Encoder Stall Detection

Time

0.0~2.0sec

0.1 ○ ○ ○ ○

03.07 Encoder Slip Range

(PGF4)

0~50% (0:Disable)

50

○ ○ ○ ○

03.08 Encoder Slip Detection

Time

0.0~10.0sec

0.5 ○ ○ ○ ○

03.09 Encoder Stall and Slip Error

Treatment

0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop

2

○ ○ ○

03.10 Door Width Auto-tuning

Frequency

0.10~120.00Hz 5.0

○ ○ ○ ○ ○

03.11 Door Width Auto-tuning

0: Disable
1: Enable

0

○ ○ ○ ○ ○

03.12 Door Width Pulse (Unit:1) 1~9999 8800 ○ ○ ○ ○ ○
03.13 Door Width Pulse

(Unit:10000)

0~9999 (Unit:10000)

0

○ ○ ○ ○ ○