Chapter 4 Parameter Settings|DD Series


4-25

5: Display output power (kW)

6: Display motor angle speed (HU)

7: Display the drive’s estimated output torque (kg-m)

8: Display PG pulse input position

9: Display the electrical angle

10: Display IGBT temperature(oC)

11: Display digital input ON/OFF status

12: Display digital output ON/OFF status

13: Display current multi-step speed

14: Display the corresponding CPU pin status of digital input

15: Display the corresponding CPU pin status of digital input

16:Actual output voltage when malfunction

17: Actual DC-BUS voltage when malfunction

18: Actual output frequency when malfunction

19: Actual output current when malfunction

20: Actual frequency command when malfunction

21: Door width in % or step speed

22: Door width(pulse)

23: Over modulation indication

※Description to function 08

rpm

60

XPPR)/1000]X10= Pulse/10ms

[(

rpm=motor speed; PPR= (Encoder) pulse number per turn; 1000 (1sec= 1000ms); 10: encoder pulses
per10ms

On this page, press

to display the content of Pr.00.04 (setting 0~23) accordingly.

Software version

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: #. ##

Settings Read only (Different versions will display differently)

Password Input

Control mode

VF

VFPG

SVC FOCPG

FOCPM

Factory setting: 0

Settings 0~9999

0~2:times of wrong password

Password Set

Control mode

VF VFPG SVC FOCPG FOCPM

Factory setting: 0

Settings 0~9999

0: No password set or successful input in Pr.00-06

1: Password has been set

The function of this parameter is to input the password that is set in Pr.0-07. Input the correct password

here to enable changing parameters. You are limited to a maximum of 3 attempts. After 3 consecutive

failed attempts, a blinking “PcdE” will show up to force the user to restart the AC motor drive in order to

try again to input the correct password.

To set a password to protect your parameter settings.

If the display shows 00, no password is set or password has been correctly entered in Pr.0-06. All

parameters can then be changed, including Pr.0-07.

The first time you can set a password directly. After successful setting of password the display will show

01.

Be sure to record the password for later use.

To cancel the parameter lock, set the parameter to 00 after inputting correct password into Pr. 0-07.