04 door open parameters – Delta 1.07 VFD-D D User Manual
Page 34
Chapter 4 Parameter Settings|DD Series
4-10
04 Door Open Parameters
This parameter can be set during operation.
Parameter
Explanation
Settings
Factory
Setting VF VFP SVC FO
C
FO
C
04.00 Door Open by Initial Speed 0.00~120.0Hz 2.00
○ ○ ○ ○ ○
04.01 Door Open Distance by
Initial Speed
0~65535 (Unit: pulses number)
300 ○ ○ ○ ○ ○
04.02 Door Open Time by Initial
Speed
0~20.0s 1.0
○ ○ ○ ○ ○
04.03 Door Open High Speed 1
0.00~120.0Hz 15.00
○ ○ ○ ○ ○
04.04 Door Open by Final Speed
Begins
0.0~100.0% (Door width setting in %)
90.0 ○ ○ ○ ○ ○
04.05 Door Open Final Speed
0.00~120.0Hz 5.00 ○ ○ ○ ○ ○
04.06 Door Open by Holding
Speed Begins
0.0~100.0% (Door width setting in %)
95.0 ○ ○ ○ ○ ○
04.07 Door Open Holding Speed 0.00~120.0Hz 2.00 ○ ○ ○ ○ ○
04.08 Door Open Acceleration
Time 1
0.1~3600sec 1.0 ○ ○ ○ ○ ○
04.09 Door Open Deceleration
Time 1
0.1~3600sec 1.0 ○ ○ ○ ○ ○
04.10 Door Open Holding Torque
Level
0.0~150.0% (AC drive’s rated current)
50.0 ○ ○ ○ ○ ○
04.11 Door Open Holding Torque 0.0~100.0% (AC drive’s rated current)
30.0 ○ ○ ○ ○ ○
04.12 Response Time of Door
Open Holding Torque
0.01~10.00sec 0.20 ○ ○ ○ ○ ○
04.13 Door Open High Speed 2
0.00~400.0Hz 30.00 ○ ○ ○ ○ ○
04.14 Door Open Acceleration
Time 2
0.1~3600sec 1.0 ○ ○ ○ ○ ○
04.15 Door Open Deceleration
Time 2
0.1~3600sec 1.0 ○ ○ ○ ○ ○
04.16 Door Open Holding Torque 2 0.0~150.0% (AC drive’s rated current)
0.0 ○ ○ ○ ○ ○
04.17 Door Open Time-out Setting 0.0~180.0sec (0.0 sec: Disable)
0.0 ○ ○ ○ ○ ○
04.18 Holding Time for OD (Open
Door)Terminal
0.0~999.9sec (999.9 sec for always
holding)
0.0 ○ ○ ○ ○ ○
04.19 Door Open Acceleration
Time of S1 Curve
0.0~10.0sec 0.0
○ ○ ○ ○ ○
04.20 Door Open Acceleration
Time of S2 Curve
0.0~10.0sec 0.0
○ ○ ○ ○ ○
04.21 Door Open DC Brake
Current Level
00~100% 0
○ ○ ○
04.22 Door Open DC Brake Time
when Startup
0.0~60.0sec 0.0
○ ○ ○ ○ ○
04.23 Door Open DC Brake Time
when Stopping
0.0~60.0sec 0.0
○ ○ ○ ○ ○
04.24 Door Open DC Brake
Starting Frequency
0.00~120.00Hz 0.00
○ ○ ○ ○