05
Door Close Parameters
This parameter can be set during operation.
Parameter
Explanation
Settings
Factory
Setting VF VFP SVC FO
C
FO
C
05.00 Door Close Initial Speed 0.00~120.0Hz 2.00
○ ○ ○ ○ ○
05.01 Door Close Distance by
Initial Speed
0~65535 (Unit: pulses number)
0
○ ○ ○ ○ ○
05.02 Door Close Time by Initial
Speed
0~20.0s 0
○ ○ ○ ○ ○
05.03 Door Close High Speed 1 0.00~120.0Hz 15.00
○ ○ ○ ○ ○
05.04 Door Close by Final Speed
Begins
0.0~100.0% (Door width setting in %)
10.0 ○ ○ ○ ○ ○
05.05 Door Close Final Speed
0.00~120.0Hz 5.00
○ ○ ○ ○ ○
05.06 Door Close by Holding
Speed Begins
0.0~100.0% (Door width setting in %)
5.0 ○ ○ ○ ○ ○
05.07 Door Close Holding Speed 0.00~120.0Hz 2.00
○ ○ ○ ○ ○
05.08 Door Close Acceleration
Time 1
0.1~3600sec 1.0
○ ○ ○ ○ ○
05.09 Door Close Deceleration
Time 1
0.1~3600sec 1.0
○ ○ ○ ○ ○
05.10 Door Close Holding Torque
Level 1
0.0~150.0% (Drive’s rated current)
50.0 ○ ○ ○ ○ ○
05.11 Door Close Holding
Torque 1
0.0~100.0% (Drive’s rated current)
20.0 ○ ○ ○ ○ ○
05.12 Response Time of Door
Close Holding Torque
0.01~10.00sec 0.20 ○ ○ ○ ○ ○
05.13 Door Close High Speed 2 0.00~120.0Hz 30.00
○ ○ ○
05.14 Door Close Acceleration
Time 2
0.1~3600sec 1.0
○ ○ ○ ○ ○
05.15 Door Close Deceleration
Time 2
0.1~3600sec 1.0
○ ○ ○ ○ ○
05.16 Door Close Holding
Torque Level 2
0.0~150.0% (Ac drive’s rated current)
0.0 ○ ○ ○ ○ ○
05.17 Door Close Time-out
Setting
0.0~180.0sec (0.0sec:Disable)
0.0 ○ ○ ○ ○ ○
05.18 Holding Time for CD (Close
Door)Terminal
0.0~999.9sec (999.9sec is always
holding)
0.0 ○ ○ ○ ○ ○
05.19 Door Close Acceleration
Time of S1 Curve
0.0~10.0sec 0.0
○ ○ ○ ○ ○
05.20 Door Close Acceleration
Time of S2 Curve
0.0~10.0sec 0.0
○ ○ ○ ○ ○
05.21
Door Close DC Brake
Current Level
0~100% 0
○ ○ ○
05.22 Door Close DC Brake Time
when Startup
0.0~60.0sec 0.0
○ ○ ○ ○ ○
05.23 Door Close DC Brake Time
when Stopping
0.0~60.0sec 0.0
○ ○ ○ ○ ○