Delta 1.07 VFD-D D User Manual

Page 66

background image

Chapter 4 Parameter Settings|DD Series


4-42

10

OD command

Active when the operation direction is door open.

11

CD command

Active when the operation direction is door close.

12

Demo Indication

Active when the drive is in demo mode.

13

Demo complete

Active when each time door open/close is complete in demo
mode (contact closed for 0.5s only).

14

Emergency stop indication

Active when emergency stop is detected.

15

Force stop indication

Active when force stop is detected.

16

Door open complete (limit)
signal output

Active when position mode (Pr.06-11) is set to “no door close
limit signal” and the door width is greater than the setting in
Pr.04-06.
Active when position mode (Pr.06-11) is set to door close limit
signal allow and one of MI (Pr.02-01~02-05) is set to 14.

17

Door close complete (limit)
signal output

Active when position mode (Pr.06-11) is set to “no door close
limit signal” and the door width is less than Pr.05-06 setting
during the door close.
Active when position mode (Pr.06-11) is set to door close limit
signal allow and one of MI (Pr.02-01~02-05) is set to 15.

18

Door close error

Active when door close error. (Includes door reopen and not
reopen).

19

Position complete signal

Active when positioning is completed after drive power is on or
PGEr. This function is valid when Pr.00-10=00.

20

Position Detection 1(for door
close only)

Active when door close width is lower than Pr.06-14 (valid when
door close).

21

Position Detection 2(for door
close only)

Active when door close width is lower than Pr.06-15 (valid when
door close).

22

Position Detection 3(for door
close only))

Active when door close width is lower than Pr.06-16 (valid when
door close).

23

Position Detection 1(for door
open only)

Active when door close width is lower than Pr.06-14 (valid when
door open).

24

Position Detection 2(for door
open only)

Active when door close width is lower than Pr.06-14 (valid when
door open).

25

Position Detection 3(for door
open only)

Active when door close width is lower than Pr.06-14 (valid when
door open).

26

PG feedback error

Active when PG feedback signal error is detected

27

output signal when unable to
open the door

28

over torque (OT1)

Digital Output Direction

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 0

Settings 00~65535

This parameter is set via bit setting. If a bit is 1, the corresponding output acts in the opposite way.

Example:

If Pr02-08=1 (operation indication) and Pr.02-13=0, Relay 1 RA-RC is closed when the drive runs and is

open when the drive is stopped.

If Pr02-08=1 and Pr02-13=1, Relay 1 RA-RC is open when the drive runs and is closed when the drive is

stopped.

Position Detection Signal 1

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 25.0

Settings 0.0~100.0%

Position Detection Signal 2