Chapter 5 Troubleshooting |DD Series

5-10

5-9 Motor is not Running

Motor cannot run

Check if CE01
displays
normally

No

No

No

No

No

No

No

No

No

No

No

No

No

No

No

Check if non-fuse
breaker and magnetic
contactor are ON

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Set them to ON

Reset after clearing
fault and then RUN

Check if there is any
fault code displayed

Check if input
voltage is normal

Check if any faults
occur, such as
Lv, PHL or
disconnection

Input "RUN"
command
by keypad

It can run when
no faults occur

If jumper or DC
reactor is connected
between +1 and +2/B1

Use jumper
or DC reactor

Press RUN key to
check if it can run

Maybe AC motor drive has malfunction or misoperation
due to noise. Please contact DELTA.

Press UP key to
set frequency

Yes

Modify frequency
setting

Check if input FWD
or REV command

Check if the wiring
of terminal MI1
and between
MI2-DCM is correct

Yes

Change switch or relay

Set frequency or not

Press UP to
check if motor
can run

Correct connection

Check if the parameter
setting and wiring of
analog signal and
multi-step speed
are correct

No

Motor has malfunction

No

Maybe AC motor drive has malfunction.
Please contact DELTA.

Check if there is any
output voltage from
terminals U, V and W

Check if motor
connection
is correct

No

Connect correctly

Check if the setting
of torque
compensation
is correct

Increase the setting of
torque compensation

Motor is locked due to large load, please reduce load.
For example, if there is a brake, check if it is released.

If load is too large

if upper bound freq.
and setting freq. is
lower than the min.
output freq.

Yes

Change defective
potentiometer and
relay