beautypg.com

3 control circuit terminal – Delta 1.07 VFD-D D User Manual

Page 20

background image

Chapter 2 WiringDD Series

2-7

2-3 Control Circuit Terminal

RA1 RB1

RC1

RA2 RB2

RC2

MO1

MO2

MO3

MCM

MI1

MI2

MI3

MI4

MI5

CD

OD

24V

COM

DCM

Torque

Wire Gauge

5 kgf-com (6.9 in-lbf)

18-12 AWG (0.8107-3.332mm

2

)

Terminal

Symbol

Terminal Function

Factory Setting (NPN Mode)

OD

Door Open to Stop

OD-DCM: ON: Open ; OFF: Decelerate to stop

CD

Door Close to Stop

CD-DCM: ON: Close; OFF: Decelerate to stop

MI1

Multi-function Input 1

MI2

Multi-function Input 2

MI3

Multi-function Input 3

MI4

Multi-function Input 4

MI5

Multi-function Input 5

Refer to Pr. 02-01~02-05 for programming of
Multi-function Inputs 1~5.
ON: the input voltage is 24Vdc(Max: 30Vdc), input

impedance is 3.75kΩ

OFF: leakage current tolerance is 10μA.

COM

Digital control signal common Common for digital inputs

+E24V Digital Signal Common

+24V 80mA

DCM

Digital Signal Common

Common for digital inputs

RA1

Multi-function Relay1 output
(N.O.) a

RB1

Multi-function Relay1 output
(N.C.) b

RC1

Multi-function Relay1
common

RA2

Multi-function Relay2 output
(N.O.) a

RB2

Multi-function Relay2
common

RC2

Multi-function Output 1
(Photocoupler)

Resistive Load:
5A(N.O.)/3A(N.C.) 240VAC
5A(N.O.)/3A(N.C.) 24VDC
Inductive Load:
1.5A(N.O.)/0.5A(N.C.) 240VAC
1.5A(N.O.)/0.5A(N.C.) 24VDC

To output any monitoring signal including in operation ,
frequency attained, overload indicator…etc, please refer
to Pr.02-08~02-12 for MO selection.

MO1

Multi-function Output 1
(Photocoupler)

MO2

Multi-function Output 2
(Photocoupler)

MO3

Multi-function Output 3
(Photocoupler)

To output any monitoring signal including in operation ,
frequency attained, overload indicator…etc, please refer
to Pr.03-01for MO selection.

MO1~MO2-DCM

MO1~MO2

MCM

Internal Circuit

Max: 48Vdc

50mA

MCM Multi-function output common Max 48Vdc 50mA

* Analog control signal wiring size: 18 AWG (0.75 mm

2