02 input/output parameters – Delta 1.07 VFD-D D User Manual
Page 30
Chapter 4 Parameter Settings|DD Series
4-6
02 Input/Output Parameters
: This parameter can be set during operation.
Parameter
Explanation
Settings
Factory
Setting VF VFP SVC FO
C
FO
C
02.00 2-wire/3-wire Operation
Control
0: 2-wire mode 1 (when power is on,
operation begins)
1: 2-wire mode 1 (when power is on, no
operation)
2: 2-wire mode 2 (when power is on,
operation begins)
3: 2-wire mode 2 (when power is on, no
operation)
0
○ ○ ○ ○ ○
02.01 Multi-Function Input 1 (MI1) 0: No function
14
○ ○ ○ ○ ○
02.02 Multi-Function Input 2 (MI2) 1: Multi-step speed command 1
15
○ ○ ○ ○ ○
02.03 Multi-Function Input 3 (MI3) 2: Multi-step speed command 2
16
○ ○ ○ ○ ○
02.04 Multi-Function Input 4 (MI4) 3: Multi-step speed command 3
17
○ ○ ○ ○ ○
02.05 Multi-Function Input 5 (MI5) 4: Multi-step speed command 4
0
○ ○ ○ ○ ○
5: Fault reset
○ ○ ○ ○ ○
6: Low speed operation
○ ○ ○ ○ ○
7: OD/CD command for low speed
operation
○ ○ ○ ○ ○
8: 1st, 2nd acceleration/deceleration time
selection
○ ○ ○ ○ ○
9: Force stop (NO) input
○ ○ ○ ○ ○
10: Demo mode
○ ○ ○ ○ ○
11: Emergency stop (NO) input
○ ○ ○ ○ ○
12: Source of operation command
(Keypad/External terminals)
○ ○ ○ ○ ○
13: Parameter lock enable (NC)
○ ○ ○ ○ ○
14: Door open complete signal
○ ○ ○ ○ ○
15: Door close complete signal
○ ○ ○ ○ ○
16: Door open speed switch signal
○ ○ ○ ○ ○
17: Door close speed switch signal
○ ○ ○ ○ ○
18: Open allowance signal
○ ○ ○ ○ ○
19: Screen signal input
○ ○ ○ ○ ○
20: Door curve signal input for 2nd set
door open/close
○ ○ ○ ○ ○
21: Reset signal input
○ ○ ○ ○ ○
22: Input system security circuit
confirmation signal (DCC)
○ ○ ○ ○ ○
23
: Input enforced door closing signal
(NU
D)
○ ○ ○ ○ ○
02.06 Digital Terminal Input
Debouncing Time
0.001~30.000sec 0.005
○ ○ ○ ○ ○
02.07 Digital Input Operation
Direction
0~65535 60
○ ○ ○ ○ ○
02.08 Multi-function Output
(Relay1)
0: No function
16
○ ○ ○ ○ ○