beautypg.com

3 over voltage (ov) – Delta 1.07 VFD-D D User Manual

Page 109

background image

Chapter 5 Troubleshooting |DD Series

5-4

5-3 Over Voltage (ov)

Over voltage

Yes

No

Yes

No

No

No

If voltage is within
specification

Reduce voltage to
be within spec.

If over-voltage is occurred without load

Maybe AC motor drive
has malfunction or
misoperation due to
noise. Please contact
with DELTA.

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

When OV occurs, check if the
voltage of DC BUS is greater
than protection value

If OV occurs when
sudden acceleration
stops

Increase
deceleration
time

Increase setting time

Increase
acceleration
time

Reduce moment
of inertia

Reduce moment of load inertia

Use braking unit or DC braking

Need to check control method. Please contact DELTA.

Need to considerate to
use braking unit and
DC braking