beautypg.com

Delta 1.07 VFD-D D User Manual

Page 69

background image

Chapter 4 Parameter Settings|DD Series


4-45

Encoder Feedback Fault Treatment (PGF1, PGF2)

Control mode

VFPG

FOCPG

Factory setting: 2

Settings

0: Warn and keep operation

1: Warn and ramp to stop

2: Warn and stop operation

Detection Time for Encoder Feedback Fault

Control mode

VFPG

FOCPG

FOCPM

Factory setting: 1.0

Settings 0.0~10.0sec

When PG loss, encoder signal error, pulse signal setting error or signal error, if time exceeds the

detection time for encoder feedback fault (Pr.03-04), the PG signal error will occur. Refer to the Pr.03-03

for encoder feedback fault treatment.

Encoder Stall Level (PGF3)

Control mode

VFPG

SVC

FOCPG

FOCPM

Factory setting: 115

Settings 0~120% (0: disable)

This parameter determines the maximum encoder feedback signal allowed before a fault occurs. (max.

output frequency Pr.01-31 =100%)

Encoder Stall Detection Time

Control mode

VFPG

SVC

FOCPG

FOCPM

Factory setting: 0.1

Settings 0.0~2.0sec

Encoder feedback error (Max. output frequency Pr.01-31=100%)

Encoder Slip Range (PGF4)

Control mode

VFPG

SVC

FOCPG

FOCPM

Factory setting: 50

Settings 0~50%

(0:disable)

Encoder feedback error (Max. output frequency Pr.01-31=100%)

Encoder Slip Detection Time

Control mode

VFPG

SVC

FOCPG

FOCPM

Factory setting: 0.5

Settings 0.0~10.0sec

Encoder feedback error (Max. output frequency Pr.01-31=100%)

Encoder Stall and Slip Error Treatment

Control mode

VFPG

SVC

FOCPG

Factory setting: 2

Settings Encoder PG signal feedback error (Max. output frequency Pr.01-31=100%)

0: Warn and keep operation

1: Warn and ramp to stop

2: Warn and coast to stop

When the value of (rotation speed – motor frequency) exceeds Pr.03-07 setting, detection time exceeds

Pr.03-08 or motor frequency exceeds Pr.03-05 setting, it will start to accumulate time. If detection time

exceeds Pr.10-06, the encoder feedback signal error will occur. Refer to Pr.03-09 encoder stall and slip

error treatment.

Door Width Auto-tuning Frequency

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 5.0

Settings 0.10~120.00Hz

This parameter is the frequency of motor when using door width auto-tuning function.

D

oor Width Auto-tuning

Control mode VF

VFPG

SVC

FOCPG

FOCPM

Factory setting: 0