Delta 1.07 VFD-D D User Manual
Page 31
Chapter 4 Parameter Settings|DD Series
4-7
Parameter
Explanation
Settings
Factory
Setting VF VFP SVC FO
C
FO
C
02.09 Multi-function Output
(Relay2)
1: AC drive in operation
17
○ ○ ○ ○ ○
02.10 Multi-function Output
(MO1)
2: Zero speed frequency signal
(including STOP)
0
○ ○ ○ ○ ○
02.11 Multi-function Output
(MO2)
3: AC drive ready
0
○ ○ ○ ○ ○
02.12 Multi-function Output
(MO3) (Communication)
4: Low voltage warning(Lv)
0
○ ○ ○ ○ ○
5: Fault indication
○ ○ ○ ○ ○
6: Overhead warning (Pr.06.09)
○ ○ ○ ○ ○
7: Detection of braking resistor action
level
○ ○ ○ ○ ○
8: Warning indication
○ ○ ○ ○ ○
9: Over voltage warning
○ ○ ○ ○ ○
10: OD command
○ ○ ○ ○ ○
11: CD command
○ ○ ○ ○ ○
12: Demo Indication
○ ○ ○ ○ ○
13: Demo complete
○ ○ ○ ○ ○
14: Emergency stop indication
○ ○ ○ ○ ○
15: Force stop indication
○ ○ ○ ○ ○
16: Door close complete (limit) signal
output
○ ○ ○ ○ ○
17: Door open complete (limit) signal
output
○ ○ ○ ○ ○
18: Door close error
○ ○ ○ ○ ○
19: Position Complete Signal
○ ○ ○ ○ ○
20: Position Detection 1(for door close
only)
○ ○ ○ ○ ○
21: Position Detection 2(for door close
only)
○ ○ ○ ○ ○
22: Position Detection 3(for door close
only))
○ ○ ○ ○ ○
23: Position Detection 1(for door open
only)
○ ○ ○ ○ ○
24: Position Detection 2(for door open
only)
○ ○ ○ ○ ○
25: Position Detection 3(for door open
only)
○ ○ ○ ○ ○
26: PG feedback error
○ ○ ○ ○ ○
27: output signal when unable to open
the door
○ ○ ○ ○ ○
28: over torque (OT1)
○ ○ ○ ○ ○
02.13 Multi-function Output
Direction
0~65535 0
○ ○ ○ ○ ○
02.14 Position Detection Signal 1 0.0~100.0% 25.0 ○ ○ ○ ○ ○
02.15 Position Detection Signal 2 0.0~100.0% 12.5 ○ ○ ○ ○ ○
02.16 Position Detection Signal 3 0.0~100.0% 7.5 ○ ○ ○ ○ ○