beautypg.com

Multi-function output (mo3) – Delta 1.07 VFD-D D User Manual

Page 65

background image

Chapter 4 Parameter Settings|DD Series


4-41

Multi-function Output (MO3)

Factory setting: 0

Settings Control

mode VF VFPG SVC FOCPG FOCPM

0: No function

1: AC drive in operation

2: Zero speed frequency signal (including STOP)

3: AC drive ready

4: Low voltage warning(Lv)

5: Fault indication

6: Overhead warning (Pr.06.09)

7: Detection of braking resistor action level

8: Warning indication

9: Over voltage warning

10: OD command

11: CD command

12: Demo Indication

13: Demo complete

14: Emergency stop indication

15: Force stop indication

16: Door open complete (limit) signal output

17: Door close complete (limit) signal output

18: Door Close Error

19: Position Complete Signal

20: Position Detection 1(for door close only)

21: Position Detection 2(for door close only)

22: Position Detection 3(for door close only))

23: Position Detection 1(for door open only)

24: Position Detection 2(for door open only)

25: Position Detection 3(for door open only)

26: PG feedback error

27: output signal when unable to open the door

28: over torque (OT1)

These parameters can be used for external terminal output

Summary of Function Settings

Settings

Functions

Descriptions

0

No function

MO has no function.

01

AC drive in operation

The drive is ON when it receives voltage or operation command.

2

Zero speed frequency signal
(including STOP)

Zero speed output signals (including STOP).

3

AC drive ready

Active when the drive is ON and no abnormality detected or
abnormality is cleared.

4

Low voltage warning(Lv)

Active when the detected input voltage is too low.

5

Fault indication

Active when fault occurs.

6

Overhead warning (Pr.06.09) Active when IGBT or heat sink overheats to prevent OH turn off

the drive. When temperature higher than 85 = ON, lower than

<80 = OFF

.

7

Detection of braking resistor
action level

Active when drive begins software braking, this signal can be
used as brake module VFDB action signal or indicator.

8

Warning indication

Active when warning is detected.

9

Over voltage warning

Active when over-voltage is detected.