Tektronix AWG610 User Manual
Page 164
![background image](/manuals/216384/164/background.png)
The Graphical Waveform Editor
3-46
AWG610 Arbitrary Waveform Generator User Manual
Table 3–7 provides a description of the Waveform editor screen elements.
Table 3-7: Waveform editor screen elements
Element
Description
Activecursor position Theposition of theactivecursor in thedata record relativeto thestart of
the data record. Position is stated as point location or time depending on
the horizontal unit set with the Settings menu.
Clock frequency
The clock frequency (sample rate) used to calculate the pointĆtoĆpoint
time interval between each data point. This value is set in the Settings
menu.
Notethat this valueis not theoutput waveform frequency. Output
frequency is calculated as follows:
Freq
out
= Fre q
clk
/ points per waveform cycle
CursorĆtoĆcursor
distance
The number of data points or time between the left and right cursors.
Distance is stated as points or time depending on the horizontal unit set
with the Settings menu.
Waveform record
length
The record length of the entire waveform file, in points. Record length is
always shown as points regardless of the horizontal unit set with the
Settings menu. The default value is 1000 points.
Edit area position bar The edit area position bar is relative to the position of the displayed edit
area in the entire record length. This helps you determine where you are
in a waveform record when you do zoom operations on the display area.
Window number
The edit window number is from one to three. The maximum number of
editor windows you can open at one time is three.
Knob icon
The knob icon is displayed when you can use the general purpose knob
to change a highlighted field.
Left cursor position
field and data value
Theposition of theleft cursor and thedata valueat that position. Cursor
position 0 is thestart of thedata record. Position is stated as point
location or time depending on the horizontal unit set with the Settings
menu.
You use the TOGGLE frontĆpanel button to select between the left or
right cursor. When the left cursor is active, you can use the general
purposeknob or theKeypad buttons to changethecursor position.
Marker display
The marker display is a graphical representation of the marker data
values.
Right cursor position
field and data value
Theposition of theright cursor and thedata valueat that position.
Cursor position 0 is thestart of thedata record. Position is stated as
point location or time depending on the horizontal unit set with the
Settings menu.
You use the TOGGLE frontĆpanel button to select between the left or
right cursor. When the right cursor is active, you can use the general
purposeknob or theKeypad buttons to changethecursor position.