beautypg.com

Emptying the effluent tanks, Emptying the effluent tanks -51 – Kodak SRP 30 User Manual

Page 304

background image

Maintenance

Emptying the Effluent Tanks

WARNING:

NOTE:

Wear protective gloves, a rubber apron, and goggles when you
empty the effluent tanks.

As soon as one of the effluent tanks is full, a message appears on the screen
advising that this tank must be emptied.

It is possible to touch Clear to suppress the message and to continue the
work for a while. When the message appears for the third time, it can no
longer be cleared.

1. Open the front door at the bottom left of the paper processor. Position (1) marks

the drain valves you must open to empty the effluent tanks.

2. Put a bucket under the respective drain valve.

3. Open the valve and empty the tank.

4. Close the valve.

5. Do Steps 2–4 with the adjacent second valve.

CAUTION:

IMPORTANT:

Do not open both valves at the same time. The volume of both
tanks is 20 L.

Do not open the drain valves in the vertical position on the right
side. They are used to empty the processing tanks CD, BX and
SB1 to SB4, for example, when a completely new tank preparation
has to be filled into single or all tanks.

Check the pan (2): If it is full even though you emptied the tanks in
time, call a technician. The hose systems could be defective.

6. Dispose of the effluent by following procedures specific to your lab. See Disposal

of Chemicals and Containers in Regulatory and Safety Information.

KODAK PROFESSIONAL SRP 30 Laser Printer

8-51