beautypg.com

Daily maintenance, Cleaning the aps film mask, Daily maintenance -5 – Kodak SRP 30 User Manual

Page 258: Cleaning the aps film mask -5

background image

Maintenance

Daily Maintenance

Cleaning the APS Film Mask

Purpose:

To correctly detect magnetic data.

Necessary tools:

KODAK PROFESSIONAL Magnetic Read Head Cleaner for SRP 30 (Catalog No.
190 8938)

Isopropyl alcohol

CAUTION:

WARNING:

IMPORTANT:

Use only isopropyl alcohol. Other cleaning agents will damage
the rubber transport rollers TR4 and TR5 and dissolve the
bonding of the cleaning strips.

Dissolved glue will irreversibly contaminate the magnetic head.

Avoid spilling isopropyl alcohol on the surface of the printer
because it could damage the paint. Wipe up any spills
immediately.

Isopropyl alcohol is a flammable liquid. It can cause eye
irritation and dry skin. Wash hands with soap and water
following maintenance procedures. See the manufacturer's
Material Safety Data Sheet (MSDS) for additional safe handling
and first aid information.

Clean the magnetic head every day so that possible deposits cannot dry and make
the cleaning more difficult.

1. Check that the APS film mask is inserted.

2. Touch:

Print mode

Manual positioning

Do Step 4 within 20 seconds of Step 3 to avoid evaporation of the
isopropyl alcohol.

3. Apply four drops of isopropyl alcohol to the read head cleaner with an eye

dropper as illustrated.

4. Insert the read head cleaner into the film feeder dry side first so that it dries the

magnetic head when it is ejected.

The printer pulls in the read head cleaner into the film mask the same as with
film.

KODAK PROFESSIONAL SRP 30 Laser Printer