4. The lamp mount (1) is secured to the holder by magnets. Pull the lamp mount (1)

out of the holder and remove the old lamp with a clean cloth.

5. Check the lamp socket (2).

a. If the lamp socket or the contacts show burning stains caused by heat, this

indicates contact problems that may have a negative impact on the print
result.

b. If required, have the lamp socket replaced by a service technician.

CAUTION:

To avoid fingerprints, do not touch the lamp with your bare
hands. Use the protective foil that comes with the lamp or a lint-
free cloth.

6. Install the new lamp in the lamp mount.