beautypg.com

Motorola 68P02958C00-B User Manual

Page 98

background image

Site Configuration

5-41

67

European standard

Hanging up an unused line by INITIATOR after <1-60> Sec

[20]:

A period of quiet time at the end of which the initiator of the conversation hangs up the phone.

Hanging up an unused line by RESPONDER after <1-120> Sec

[120]:

A period of quiet time at the end of which the responder hangs up the phone.

Number of dial retries <1-10>

[3]:

The number of times the number will be redialed (in addition to the first time) in order to
establish communications with a unit.

Interval between retries <1-30> Sec

[7]:

Interval of time between a failure to establish communications (BUSY, NO ANSWER) and
the next dialing. However, if a line is busy and another line is available, the attempt is renewed
through the other line without delay.

Number of rings for answer <1-255>

[2]:

Number of rings to wait for the called party to answer.

Wait for data carrier <1-255> *100mSec

[250]:

A waiting period between the end of dialing and the reception of the connection signal from
the answering modem. After this period, the attempt is considered to be a failure.

Lost carrier to hang-up delay <1-255> *100mSec

[20]:

The period of time during which disconnection is delayed after the carrier is lost.

Wait for dial tone <1-255> *100mSec

[50]:

The amount of time the calling device should wait until it gets the dial tone.

Wait time after hang-up <1-255> *100mSec

[35]:

The minimum time that should elapse between two attempts to obtain a line.

Number of dial tone retry <1-20>

[3]:

Number of retries to obtain a line.

Blind dialing

[NO]:

The valid values are:

NO

Wait for the dial tone

YES

Dial after a pre-defined period of time (blind dialing).

HDLC 'RTS' control

[AUTO]:

The valid values are:

AUTO

RTS runs automatically before the transmission and terminates after the
transmission