Error Messages
C-143
Error #282:
Unoperational Communication CHANNEL on: PORT #%% CONTROL=%%
STATUS=%%
The port is transferred to software mode. This message is displayed if CD is not
active.
Error #283:
Unoperational CHANNEL Internal LOOP on: PORT #%% CONTROL=%%
STATUS=%%
Incompatibility between the frame that was sent and received by the internal
loop.
Error #284:
Unoperational CHANNEL External LOOP on: PORT #%% CONTROL=%%
STATUS=%%
Incompatibility between the frame that was sent and received by the external
loop.
Error #285:
Unsuccessful CHANNEL Configuration on: PORT #%% COMMAND=%%
ANSWER=%%
Internal modem does not exist or illegal parameters were downloaded.
Error #286:
Uncontrollable CHANNEL Configuration on: PORT #%% COMMAND=%%
DATA=%%
Problem in the internal modem.
Error #287:
No response from internal DPSK modem on: port #%% command=%%
data=%%
Problem in the internal modem-piggyback plug in Port Type unit for Port 3.
Error #288:
An Incompatible piggyback was found.
The configuration was defined for Radio model: R%%
The installed piggyback ID is: %%
(see the table below for conversion)
The following table lists the available IDs:
Piggyback ID
Description
1
Spread Spectrum (Aironet) R202
2
Spread Spectrum (Aironet) R100
3
Spread Spectrum (Aironet) R202 AND DPSK interface
4
Spread Spectrum (Aironet) R100 AND DPSK interface
Other
Unknown, invalid or no piggiback
For Spread Spectrum radio only (MOSCAD-L only).
Error #289:
Could not program the spread spectrum (aironet) radio successfully. The
readback registers value was different from the written ones.
Piggyback cannot be programmed. Switch or fix piggyback.