Motorola 68P02958C00-B User Manual
Page 463

Error Messages
C-171
Error #1602:
Failed testing INTRAC modem piggyback (CTS signal)
Hardware problem in modem.
Error #1638:
INTRAC system table: invalid radio warmup time (R_Ptt) %%
Invalid R_Ptt value in the INTRAC system tables (database builder).
Possible range: 10-60000 msec.
Error #1639:
INTRAC system table: invalid radio override time (ROvrid) %%
Invalid ROvrid value in the INTRAC system tables (database builder).
Possible range: 10-60000 msec.
Error #1640:
INTRAC system table: invalid radio quiet time (RQuiet) %%
Invalid RQuiet value in the INTRAC system tables (database builder).
Possible range: 0-60000 msec.
Error #1641:
INTRAC system table: invalid line warmup time (L_Ptt) %%
Invalid L_Ptt value in the INTRAC system tables (database builder).
Possible range: 10-60000 msec.
Error #1642:
INTRAC system table: invalid line override time (LOvrid) %%
Invalid LOvrid value in the INTRAC system tables (database builder).
Possible range: 10-60000 msec.
Error #1643:
INTRAC system table: invalid line quiet time (LQuiet) %%
Invalid LQuiet value in the INTRAC system tables (database builder).
Possible range: 0-60000 msec.
Error #1700:
Failed initiating GPS port
Port 2, connected to GPS, cannot be initialized, because of hardware problem.
Error #1701:
Transmission failure to GPS
Transmission to GPS failed because of hardware problem.
Error #1750:
Insufficient dynamic memory. Needed: %%
Cannot allocate memory for “C” block because the size indicated in Site
Configuration is insufficient.