Buttons

15.4 Minimum startup configuration

If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.

The minimum startup configuration consists of the following components and
cables:

Pos. Button

Function

2

On / Off button

This button is used to switch the server on or off.

I

If the system is running an ACPI-compliant
operating system, the pressing the On / Off
button will performs a graceful shutdown.

Pressing and holding the On / Off button for
five seconds will switches the server off without
shutting down the operating system.

Field Replaceable Units (FRU)

Component

Notes

System board

no TPM or expansion cards installed

CPU with CPU heat sink
1 memory module

installed in slot 1

PSU

Table 7: Minimum startup configuration - components

Cable

Notes and reference

Front panel cable

Power cable

see section

"Replacing the power cable" on

page 239

Table 8: Minimum startup configuration - cables