3. Menu Operation

3 – 68

Operating Instructions – Rev. 1 / 7.2002

Method of procedure (only with critical patterns):

D

Run the cursor assisted Ato chromakey setup

D

First attempt manual optimization of Left SL or Right S. The purpose is to max-
imize the object density.

D

Adjustment of Chrom S, Density and Cleanup

If no satisfactory result:

D

Switch on Sel Mask and select the Mask Source in the menu

D

Check in the PVW position of the mask

D

Call the automatic selectivity adjustment Sel Auto or adjust manually Selecti-
vities-I
(inside the mask) and Selectivities-O (outside the mask). The Sel Au-
to
optimizes the selectivities independent inside and outside the mask.

Reduces the noise in the selected key color (default On).

For details refer to section Introduction.

Noise Reduct