Configuring the nqa statistics collection function – H3C Technologies H3C SR8800 User Manual
Page 40

28
Step Command
Remarks
12.
Configure a reaction entry for
monitoring the MOS value
(only supported in voice tests).
reaction item-number checked-element mos
threshold-value upper-threshold lower-threshold
[ action-type { none | trap-only } ]
NOTE:
•
NQA DNS tests do not support the action of sending trap messages. The action to be triggered in DNS
tests can only be the default one, none.
•
Only the test-complete keyword is supported for the reaction trap command in a voice test.
Configuring the NQA statistics collection function
NQA groups tests completed in a time period for a test group, and calculates the test result statistics. The
statistics form a statistics group. To view information about the statistics groups, use the display nqa
statistics command. To set the interval for collecting statistics, use the statistics interval command.
When the number of statistics groups kept reaches the upper limit and a new statistics group is to be
saved, the earliest statistics group is deleted. To set the maximum number of statistics groups that can be
kept, use the statistics max-group command.
A statistics group is formed after the last test is completed within the specified interval. When its hold time
expires, the statistics group is deleted. To set the hold time of statistics groups for a test group, use the
statistics hold-time command.
To configure the NQA statistics collection function:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter NQA test group view.
nqa entry admin-name
operation-tag
N/A
3.
Enter test type view of the test
group.
type { dlsw | dns | ftp | http |
icmp-echo | snmp | tcp |
udp-echo | udp-jitter | voice }
N/A
4.
Configure the interval for
collecting the statistics of test
results.
statistics interval interval
Optional.
60 minutes by default.
5.
Configure the maximum
number of statistics groups
that can be kept.
statistics max-group number
Optional.
2 by default.
To disable collecting NQA
statistics, set the maximum number
to 0.
6.
Configure the hold time of
statistics groups.
statistics hold-time hold-time
Optional.
120 minutes by default.
- H3C SR6600-X H3C SR6600 H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module