Configuring the rmon history statistics function, Configuring the rmon alarm function, Configuration prerequisites – H3C Technologies H3C SR8800 User Manual
Page 122
110
Step Command
1.
Enter system view.
system-view
2.
Enter Ethernet interface view.
interface interface-type interface-number
3.
Create an entry in the RMON statistics table.
rmon statistics entry-number [ owner text ]
NOTE:
•
Only one statistics entry can be created on one interface.
•
You can create up to 100 statistics entries for the device.
Configuring the RMON history statistics function
To configure the RMON history statistics function:
Step Command
1.
Enter system view.
system-view
2.
Enter Ethernet interface view.
interface interface-type interface-number
3.
Create an entry in the RMON history
control table.
rmon history entry-number buckets number interval
sampling-interval [ owner text ]
NOTE:
•
The
entry-number must be globally unique and cannot be used on another interface; otherwise, the
operation fails.
•
You can configure multiple history entries on one interface, but the values of the
entry-number
arguments must be different, and the values of the
sampling-interval arguments must be different too;
otherwise, the operation fails.
•
You can create up to 100 history entries for the device.
•
When you create an entry in the history table, if the specified buckets
number argument exceeds the
history table size supported by the device, the entry is created. However, the validated value of the
buckets
number argument that corresponds to the entry is the history table size supported by the device.
Configuring the RMON alarm function
Configuration prerequisites
•
To enable the managed devices to send traps to the NMS when the NMS triggers an alarm event,
configure the SNMP agent as described in the chapter “SNMP configuration” before configuring
the RMON alarm function.
•
If the alarm variable is the MIB variable defined in the history group or the Ethernet statistics group,
make sure that the RMON Ethernet statistics function or the RMON history statistics function is
configured on the monitored Ethernet interface; otherwise, the creation of the alarm entry fails, and
no alarm event is triggered.
- H3C SR6600-X H3C SR6600 H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module