Configuration procedure, Displaying and maintaining rmon – H3C Technologies H3C SR8800 User Manual
Page 123

111
Configuration procedure
To configure the RMON alarm function:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Create an event
entry in the event
table.
rmon event entry-number [ description string ] { log |
log-trap log-trapcommunity | none | trap trap-community }
[ owner text ]
N/A
3.
Create an entry in
the alarm table or
private alarm
table.
•
Create an entry in the alarm table:
rmon alarm entry-number alarm-variable
sampling-interval { absolute | delta } rising-threshold
threshold-value1 event-entry1 falling-threshold
threshold-value2 event-entry2 [ owner text ]
•
Create an entry in the private alarm table:
rmon prialarm entry-number prialarm-formula
prialarm-des sampling-interval { absolute | changeratio
| delta } rising-threshold threshold-value1 event-entry1
falling-threshold threshold-value2 event-entry2
entrytype { forever | cycle cycle-period } [ owner text ]
Use at least one
command.
NOTE:
•
A new entry cannot be created if its parameters are identical with the corresponding parameters of an
existing entry. See
for the parameters to be compared for different entries.
•
The system limits the total number of each type of entries (See
for the detailed numbers). When
the total number of an entry reaches the maximum number of entries that can be created, the creation
fails.
Table 3 Restrictions on the configuration of RMON
Entry
Parameters to be compared
Maximum number of entries
that can be created
Event
Event description (description string), event type (log, trap,
logtrap or none) and community name (trap-community or
log-trapcommunity)
60
Alarm
Alarm variable (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute or delta),
rising threshold (threshold-value1) and falling threshold
(threshold-value2)
60
Prialarm
Alarm variable formula (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute, changeratio
or delta), rising threshold (threshold-value1) and falling
threshold (threshold-value2)
50
Displaying and maintaining RMON
- H3C SR6600-X H3C SR6600 H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module