Outputting system information to the web interface – H3C Technologies H3C SR8800 User Manual
Page 195
183
Step Command
Remarks
5.
Configure the output rules of
the system information.
info-center source { module-name |
default } channel { channel-number
| channel-name } [ debug { level
severity | state state } * | log { level
severity | state state } * | trap
{ level severity | state state } * ] *
Optional.
See “
Default output rules of system
.”
6.
Configure the format of the
timestamp.
info-center timestamp { debugging
| log | trap } { boot | date | none }
Optional.
The time stamp format for log, trap
and debugging information is date
by default.
Outputting system information to the web interface
This feature allows you to control whether to output system information to the Web interface and which
system information can be output to the Web interface. The Web interface provides abundant search
and sorting functions; therefore, if you configure to output the system information to the Web interface,
you can view system information by clicking corresponding tabs after logging in to the device through the
Web interface.
To set to output system information to the web interface:
To do…
Use the command…
Remarks
Enter system view
system-view
N/A
Enable information center
info-center enable
Optional.
Enabled by default.
Name the channel with a specified
channel number
info-center channel
channel-number name
channel-name
Optional.
See
for default channel
names.
Configure the channel through
which system information can be
output to the Web interface
info-center syslog channel
{ channel-number |
channel-name }
Optional.
By default, system information is
output to the Web interface
through channel 6.
Configure the output rules of the
system information
info-center source { module-name |
default } channel { channel-number
| channel-name } [ debug { level
severity | state state }* | log { level
severity | state state }* | trap
{ level severity | state state }* ]*
Optional.
See “
Default output rules of system
.”
Configure the format of the time
stamp
info-center timestamp { debugging
| log | trap } { boot | date | none }
Optional.
The time stamp format for log, trap
and debugging information is date
by default.
NOTE:
You can configure to output log, trap and debugging information to a channel. However, when this
channel is bound with the output destination Web interface, after logging in through the Web interface,
you can view log information of specific types only, and other types of information will be filtered out.
- H3C SR6600-X H3C SR6600 H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module