Supporting threshold monitoring – H3C Technologies H3C SR8800 User Manual
Page 21
9
•
The application module takes actions when the tracked object changes its state.
The following describes how a static route is monitored through collaboration:
1.
NQA monitors the reachability to 192.168.0.88.
2.
When 192.168.0.88 becomes unreachable, NQA notifies it to the track module.
3.
The track module notifies the state change to the static routing module
4.
The static routing module sets the static route as invalid.
NOTE:
For more information about the collaboration and the track module, see
High Availability Configuration
Guide.
Supporting threshold monitoring
NQA supports threshold monitoring for performance parameters such as average delay jitter and packet
round-trip time. The performance parameters to be monitored are monitored elements. NQA monitors
threshold violations for a monitored element, and reacts to certain measurement conditions, for example,
sending trap messages to the network management server. This helps network administrators understand
the network service quality and network performance.
1.
Monitored elements
describes the monitored elements and the NQA test types in which the elements can be
monitored.
Table 1 Monitored elements and NQA test types
Monitored elements
Test type supported
Probe duration
Tests excluding UDP jitter test and voice test
Count of probe failures
Tests excluding UDP jitter test and voice test
Packet round-trip time
UDP jitter test and voice test
Count of discarded packets
UDP jitter test and voice test
One-way delay jitter (source-to-destination and
destination-to-source)
UDP jitter test and voice test
One-way delay (source-to-destination and destination-to-source) UDP jitter test and voice test
Calculated Planning Impairment Factor (ICPIF) (see “
)
Voice test
Mean Opinion Scores (MOS) (see “
)
Voice test
2.
Threshold types
The following threshold types are supported:
{
average—Monitors the average value of monitored data in a test. If the average value in a test
exceeds the upper threshold or goes below the lower threshold, a threshold violation occurs.
For example, you can monitor the average probe duration in a test.
{
accumulate—Monitors total number of times the monitored data violates the threshold in a test.
If the total number of times reaches or exceeds a specific value, a threshold violation occurs.
{
consecutive—Monitors the number of consecutive times the monitored data violates the
threshold since the test group starts. If the monitored data violates the threshold consecutively
for a specific number of times, a threshold violation occurs.
- H3C SR6600-X H3C SR6600 H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module