Troubleshooting flow logging, Symptom 1: no flow logs are exported – H3C Technologies H3C SR8800 User Manual
Page 208

196
No userlog export is enabled
flow:
Export Version 3 logs to log server : enabled
Source address of exported logs : 2.2.2.2
Address of log server : 1.2.3.6 (port: 2000)
total Logs/UDP packets exported : 128/91
Logs in buffer : 10
Troubleshooting flow logging
Symptom 1: No flow logs are exported
•
Analysis: Neither of the export approach is specified.
•
Solution: Configure to export the flow logs to the information center or to the log server.
Symptom 2: Flow logs cannot be exported to log server
•
Analysis: Both of the export approaches are configured.
•
Solution: Restore to the default, and then configure the IP address and UDP port number of the log
server.
This manual is related to the following products:
- H3C SR6600-X H3C SR6600 H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module