172
NOTE:
By default, the information center is enabled. An enabled information center affects the system
performance in some degree due to information classification and output. Such impact becomes more
obvious in the event that there is enormous information waiting for processing.
Classification of system information
The system information of the information center falls into the following types:
•
Log information
•
Trap information
•
Debugging information
Eight levels of system information
The information is classified into eight levels by severity. The severity levels in the descending order are
emergency, alert, critical, error, warning, notice, informational and debug. When the system information
is output by level, the information with severity level higher than or equal to the specified level is output.
For example, in the output rule, if you configure to output information with severity level being
informational, the information with severity level being emergency through informational will be output.
Table 6 Severity description
Severity Severity
value
Description
Corresponding keyword
in commands
Emergency
0
The system is unusable.
emergencies
Alert
1
Action must be taken immediately
alerts
Critical 2
Critical
conditions
critical
Error 3
Error
conditions
errors
Warning 4
Warning
conditions
warnings
Notice
5
Normal but significant condition
notifications
Informational 6
Informational
messages
informational
Debug 7
Debug-level
messages debugging
Eight output destinations and ten channels of system
information
The system supports eight information output destinations, including the console, monitor terminal
(monitor), log buffer, log host, trap buffer, SNMP module, web interface (syslog), and log file.
The system supports ten channels. The channels 0 through 5, and channel 9 are configured with channel
names, output rules, and are associated with output destinations by default. The channel names, output
rules and the associations between the channels and output destinations can be changed through
commands. In addition, you can configure channels 6, 7, and 8 without changing the default
configuration of the eight channels.
- H3C SR6600-X H3C SR6600 H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module