Configuring the nqa server, Enabling the nqa client – H3C Technologies H3C SR8800 User Manual
Page 24
12
Task Remarks
Required
Use any of the approaches
Configuring the collaboration function
Optional
Configuring threshold monitoring
Optional
Configuring the NQA statistics collection function
Optional
Configuring the history records saving function
Optional
Configuring optional parameters for an NQA test group
Optional
Required
Configuring the NQA server
To perform TCP, UDP echo, UDP jitter, or voice tests, configure the NQA server on the peer device. The
NQA server responses to the probe packets sent from the NQA client by listening to the specified
destination address and port number.
To configure the NQA server:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enable the NQA server.
nqa server enable
Disabled by default.
3.
Configure the listening
service.
nqa server { tcp-connect |
udp-echo } ip-address
port-number
The destination IP address and port
number must be the same as those
configured on the NQA client. A
listening service must be unique on
the NQA server.
Enabling the NQA client
Configurations on the NQA client take effect only when the NQA client is enabled.
- H3C SR6600-X H3C SR6600 H3C SecPath F5020 H3C SecPath F5040 H3C VMSG VFW1000 H3C WX3000E Series Wireless Switches H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module