beautypg.com

Resetting bgp l2vpn connections, Mpls l2vpn configuration examples, Example for configuring a remote ccc connection – H3C Technologies H3C S7500E Series Switches User Manual

Page 209: Network requirements, Configuration procedure

background image

5-17

Resetting BGP L2VPN Connections

To do…

Use the command…

Remarks

Reset BGP L2VPN connections

reset bgp l2vpn

{ as-number |

ip-address

|

all

|

external

|

internal

}

Available in user view

MPLS L2VPN Configuration Examples

Example for Configuring a Remote CCC Connection

Network requirements

z

The CEs are connected to the PEs through VLAN interfaces.

z

A remote CCC connection is created between CE 1 and CE 2.

The main steps for configuring a CCC remote connection are:

z

Create remote CCC connections on the PEs. No static LSP is required on the PEs.

z

Configure two static LSPs on the P device for packets to be transferred in both directions.

Figure 5-3

Network diagram for configuring a remote CCC connection

CE 1

CE 2

Remote CCC connection

PE 1

PE 2

P

Vlan-int30

Vlan-int30

Vlan-int20

Vlan-int20

Vlan-int10

Vlan-int10

Vlan-int10

Vlan-int10

Loop0

Loop0

Loop0

Device Interface IP

address

Device Interface

IP

address

CE 1

Vlan-int10

100.1.1.1/24 P

Loop0

10.0.0.2/32

PE 1

Loop0

10.0.0.1/32

Vlan-int20 10.2.2.2/24

Vlan-int30

10.1.1.1/24

Vlan-int30

10.1.1.2/24

CE 2

Vlan-int10

100.1.1.2/24 PE

2 Loop0

10.0.0.3/32

Vlan-int20

10.2.2.1/24

Configuration procedure

1) Configure

CE

1

system-view

[Sysname] sysname CE1

[CE1] interface vlan-interface 10

[CE1-Vlan-interface10] ip address 100.1.1.1 24

2) Configure PE 1

# Configure the LSR ID and enable MPLS globally.

system-view

[Sysname] sysname PE1

[PE1] interface loopback 0