beautypg.com

H3C Technologies H3C S7500E Series Switches User Manual

Page 110

background image

3-28

To do…

Use the command...

Remarks

Enable route pinning

mpls te route-pinning

Required

Disabled by default

Submit current tunnel

configuration

mpls te commit

Required.

Configuring administrative group and affinity attribute

The affinity attribute of an MPLS TE tunnel identifies the properties of the links that the tunnel can use.
Together with the link administrative group, it decides which links the MPLS TE tunnel can use. This is
done by ANDing the 32-bit affinity attribute with the 32-bit link administrative group attribute. When
doing that, a 32-bit mask is used. The affinity bits corresponding to the 1s in the mask are “do care”
bits which must be considered while those corresponding to the 0s in the mask are “don’t care” bits.

For a link to be used by a TE tunnel, at least one considered affinity bit and its corresponding
administrative group bit must be set to 1.

Suppose the affinity of an MPLS TE tunnel is 0xFFFFFFFF and the mask is 0x0000FFFF. For a link to
be used by the tunnel, the leftmost 16 bits of its administrative group attribute can be 0s or 1s, but at
least one of the rest bits must be 1.

The affinity of an MPLS TE tunnel is configured at the first node on the tunnel and then signaled to the
rest nodes through RSVP-TE.

The associations between administrative groups and affinities may vary by vendor.

Follow these steps to configure the administrative group and affinity attribute:

To do…

Use the command...

Remarks

Enter system view

system-view

––

Enter interface view of MPLS TE

link

interface

interface-type

interface-number

––

Assign the link to a link

administrative group

mpls te link administrative

group

value

Optional

The default is 0x00000000.

Exit to system view

quit

––

Enter MPLS TE tunnel interface

view

interface tunnel

tunnel-number

––