beautypg.com

Troubleshooting mpls te – H3C Technologies H3C S7500E Series Switches User Manual

Page 160

background image

3-78

Tunnel1 current state: UP

Line protocol current state: UP

Description: Tunnel1 Interface

The Maximum Transmit Unit is 1500

Internet Address is 12.1.1.1/24 Primary

Encapsulation is TUNNEL, service-loopback-group not set

Tunnel source unknown, destination 3.3.3.3

Tunnel protocol/transport CR_LSP

Last 300 seconds input: 5 bytes/sec, 0 packets/sec

Last 300 seconds output: 5 bytes/sec, 0 packets/sec

34 packets input, 2856 bytes

0 input error

34 packets output, 2856 bytes

0 output error

Troubleshooting MPLS TE

Symptom:

OSPF TE is configured but no TE LSAs can be generated to describe MPLS TE attributes.

Analysis:

For TE LSAs to be generated, at least one OSPF neighbor must reach the FULL state.

Solution:

1) Perform

the

display current-configuration

command to check that MPLS TE is configured on

involved interfaces.

2) Perform

the

debugging ospf mpls-te

command to observe whether OSPF can receive the TE

LINK establishment message.

3) Perform the display ospf peer command to check that OSPF neighbors are established

correctly.