beautypg.com

Measurement Computing eZ-Analyst rev.14.1 User Manual

Page 60

background image

4-24 Edit Menu

978791

eZ-Analyst

Edit Menu > Configuration >

FFT Setup Tab:

Integration Panel / Unit Conversion

Integration Panel – 2 Views

The left-hand view is with the scrollbar up, the right-hand view is with the scrollbar down.

Integration:

Provides the means to select integration, for example, g’s-ips-mils or
g’s-ips-in. Several other possibilities exist, as can be seen in the above
images of the Integration Panel.

Edit Menu > Configuration >

FFT Setup Tab:

Integration Panel / HPF Int1 & Int2

The High Pass Filter Integration 1 (HPF Int1) and Integration 2 (HPF Int2) are used to remove
the low frequency effects of integration. All data points that exist below the specified value
are set to zero. When “Hz” is selected for the Acquisition Analysis Frequency via radio button
on the Analyzer Tab, “Hz” is seen as the units, when “CPM” is selected for the Acquisition
Analysis Frequency via radio button on the Analyzer Tab, “CPM” appears as the HPF units.

FFT Integration Panel

HPF Int1 (Hz):

Enter a value for the cutoff amount for the first integration.

HPF Int2 (Hz):

Enter a value for the cutoff amount for the second integration.