beautypg.com

Selecting display options – Measurement Computing eZ-Analyst rev.14.1 User Manual

Page 122

background image

7-8 Waterfalls, Order Tracking, and Slice Views

878193

eZ-Analyst

Selecting Display Options

Most single-display spectrum function views (FV) offer access to toolbar buttons for selecting optional spectral
displays. To access available spectral view options:

1. Open the desired spectral function view.
2. Select a Spectrum Display mode.
3. Click the applicable toolbar button(s).
Note: If the buttons are disabled, then the function view does not support the optional spectral view

feature. For example: Time, Octave, and Windowed function views do not support the features.

A review of the related toolbar buttons follows. Note that the display examples and the status of the 4 associated
buttons, which were discussed in Chapter 5, are being repeated in this chapter for convenience.

Function

Description / Comments

31 3D

Waterfall

View

Used to bring up a 3D Waterfall display.

32 Frequency

or

Orders
Slice View

Brings up a display for a chosen frequency. This is a “slice” of the
waterfall or order tracking, taken at a given frequency (or order).

33 Spectrum

Display Split
View

Brings up a standard spectrum display plus allows for a second
display, for example: a 3D Waterfall display or a Frequency Slice.

34 Order

Tracking

or Frequency

View

Order
Tracking

This button is used to enable the Order Tracking display mode or
the Frequency View mode.

The Order Tracking display mode provides a means of displaying
data from points which are evenly spaced by RPM, instead of
increments of time. On the x-axis scale of the Order Tracking
display: 1 equals shaft RPM, 2 equals 2 x Shaft RPM, 3 equals
3 x Shaft RPM, etc.

Order Tracking presents data in the frequency domain. To use
Order Tracking a tachometer must be assigned to an enabled
channel.

Note that if the and buttons are
both enabled, eZ-Analyst displays the slice view above the order
tracking view. The Order Tracking display can be enabled from
either the Measurement (Real Time) mode or the Playback mode.

Frequency
View

The Frequency View mode is the standard eZ-Analyst spectrum
view. When this view is enabled the button appears as shown to
the immediate left.

Note: Buttons 31, 32, and 33 are enabled for most single-display spectral function views (FV). They are

never enabled for time function views as the x-axis must be in frequency. Any two of these three
functions can be displayed at the same time. See table on followig page in regared to button
combinations and resulting displays.

In regard to button # 34, to enable Order Tracking click the button after verifying the following:

o at least one tachometer is assigned to a channel
o the tach channel is enabled
o no dual-function window is open, e.g., no FRF.

This manual is related to the following products: